Product Name |
Smoke Alarm |
Type |
Standalone, Photoelectric |
Intent Use |
Residential Fire Safety |
Complied Standard |
EN14604:2005/AC:2008 |
Certificates |
CPR Certificate |
Size |
φ100*34.5mm |
Color |
White RAL9010 |
Net weight |
78g (without battery) |
Power |
1pc DC9V battery (replaceable) with 1/5 year lifetime |
Silence Function |
silence for approx 8 minutes |
Low Battery Voltage & fault indicator |
yes |
Alarm sensitivity |
0.100-0.160dB/m |
Alarm Volume |
>85dB(A) at 3 meters. |
Operation current |
<15uA (standby), <25mA (alarm) |
Operating temperature |
0 °C - 40 °C |
Operating humidity |
< 93 % |
Mounting |
Ceiling or wall |
Warranty |
3 years |
Product lifetime |
10 years |
Accessories |
Screws, dowels and battery |
5 Status of Smoke Alarm |
|
Standby Status |
Red LED flashes once every 32 seconds indicating the smoke alarm is operating properly |
Alarm & Test Status |
When the test button is pressed or when the smoke alarm senses particles of combustion and goes into alarm (constant pulsed |
Low Battery Voltage Status |
An intermittent chirp with red LED flashes once every 32 seconds. |
Fault Status |
The alarm chirps between two flashes every 32 seconds. |
Silence Mode Status |
The red LED will flash once every 8 seconds after pressing the test button in alarm status |
Problem |
Solutions |
Smoke alarm does not sound when testing NOTE: Push test button for at least 5 seconds while testing. |
Remove smoke alarm from bracket and check the battery is properly connected to battery connector. Replace the battery. If there are still failures during warranty, you can return to your retailer. If the unit is out of warranty, please replace a new alarm. |
The alarm chirps with red LED flashing once every 32 seconds. |
The battery is under low battery voltage status, please replace the battery referring to Replace Battery section. |
The alarm chirps every 32 seconds. (The alarm goes into fault mode) |
Clean smoke alarm referring to the Maintenance and Cleaning section. Change a new smoke alarm if the problem still exists. |
Smoke alarm sounds unwanted alarms intermittently or when residents are cooking, taking showers, etc. |
Press test button to pause alarm. Clean smoke alarm. Please refer to the Maintenance and Cleaning section. Move smoke alarm to new location and press test button. |
The alarm sounds different from it is used to. It starts and stops. |
Clean smoke alarm. Please refer to the Maintenance and Cleaning section. If there are still failures during warranty, you can return to your retailer. If the unit is out of warranty, please replace a new alarm. |